Tasmota Scripts for Electricity Meters
Important Notice
Scripts are only required for stromleser.tasmota.
stromleser.one does not require a script and works without additional configuration!
Script Library
All available Tasmota scripts for various electricity meter models can be found here:
https://stromleser.de/pages/scripts
Using Scripts
- Visit https://stromleser.de/pages/scripts
- Find your meter model in the list
- Copy the complete script (from
>Dto the end) - Paste into Tasmota under Tools → Edit Script
- Check "Script enable" and save
Important Notes
- Copy the complete script including all lines
- Do not add spaces before the script
- Don't forget to check "Script enable"
Script Parameters Explained
Basic Structure
+1,3,o,16,9600,SML,1
+1= Meter Number3= GPIO Pin (Default)o= Optical Interface16= RX Buffer Size9600= Baud RateSML= Protocol (Smart Message Language)1= Tasmota Sensor ID
Adjustments for Multiple Devices
Default (top):
+1,3,o,16,9600,SML,1
Bottom right:
+2,10,o,16,9600,SML,8
Bottom left:
+2,7,o,16,9600,SML,6
Missing Meters
If your meter model is not listed on stromleser.de/pages/scripts:
- Similar model: Try a script from a similar model of the same manufacturer
- Contact support: Reach out to us with the exact model designation
- Community: Ask in the Tasmota forums about experiences with your meter
New Scripts
We are continuously expanding the script library. Contact us if you need a script for a meter that is not yet supported.
Troubleshooting
Common Errors
- Spaces before the script → Remove all spaces before
>D - Incomplete script → Copy the entire script including
#at the end - Script not enabled → Don't forget to check "Script enable"
- Wrong baud rate → Some meters require different baud rates (300, 2400, etc.)
Script Test
After pasting and enabling, you should see the following values:
- Consumption (kWh) - Total electricity consumption
- Feed-in (kWh) - Fed-in energy (if available)
- Current Power (W) - Current power consumption
If no values are displayed, check:
- Position of the Stromleser on the meter
- PIN entry on the meter
- Correct script for your meter model